Monthly Operations Report
February 1998
r-,
"...'.111.'
C. RICHARD SPENCER
CLERK - TREASURER
March 26. 1998
I r-
ENVIRONMENTAL
MANAGEMENT
CORPORATION
~
701 CHAMPION ROAD
JEFFERSONVILLE, INDIANA 47130
812-285-6451
FAX 812-285-6454
IT
i "
L ',::'.
CITY()P JEFFERSONVILLE
(~City/County Building
Jeffersonville, IN 47130
EIlcl()se9- please find Environmental Management Corporation's (EMC) "Operations
'Report" for the month of February 1998, containing information on the following:
5.0
6.0
Effluentguality
,pDesign Loading Limits
Facility Operations
3.1 , Pretreatment
Preventlveand Unscheduled Maintenance
4. i 'Maintenance & Repair Expenditures
4.2' "Repair & Replacement Expenditures
4.3 'Capital Improvement Expenditures
4.4 Electrical Expenditures
"Fa.cility Safety and Training
Sewer Collection System
As always, we appreciate the opportunity to be of service to the City of Jeffersonville, and we
are available to discuss this report, or any other aspect of our operations, at the convenience
of the City.
"ENVIRONMENTAL MANAGEMENT CORPORATION
lG
q
~ "
r. '
1 _
.,
t
r
n
~ !
Jeffersonville Wastewater Treatment Facility
Monthl 0 erations Report
1.0 EFFLUENT QUALITY
During February, effluent quality was within NPDES permit limits for CBOD
and TSS concentrations. Table 1.1 summarizes, theefflue,nt quality data.
Attachment A contains Time Series" l?l()t~gf4aily Carbonaceous Biochemical
Oxygen Demand (CBOD) and Total Suspended Solids (TSS) values.
Attachment B contains Time Series Plots of Aeration Mixed Liquors Suspended
Solids (MLSS) and Sludge Volume Index (SVI).
Table 1.1
EFFLUENT QUALITY
Parameters Permit Limit Monthly
mglL Average
mglL
Carbonaceous 25 2
Biochemical Oxygen
Demand (CBOD)
Total Suspended Solids 30 2
(TSS)
Fecal Coliform 1000 272
(Colonies/ 100 ml)
Chlorine Residual .05 daily <.005
Maximum
Ammonia 3.0 .34
Flow 5.2 5.31
(MGD)
-
, = CC=,"'",'
2.0 DESIGN LOADING LIMITS
The Flows and Loadings report for May 1994 through February 1998 can be
found in Attachment C.
3.0 FACILITY OPERATIONS
Jeffersonville Wastewater 'Treatment Facility
Monthl 0 erations Report
Attachment D contains a listof septic haulers that discharged at the facility
during the month of February.
During February the treatment processes
performed well. The fac:ility did experience
several high peak flows events ciuring the
month. The high peak flows are a result of
rainfall events during the month.
The poor sludge settleability, high Sludge
Volume Index's (SVI's) and foaming in the
treatment process is still a concern at the
wastewater treatment facility. We continue
to work with the local industries tq elirl1inate th~tg}(ic ~i~c:harges, that create the
high SVI's and foaming. The influent loadings at the head works of the facility
are also still relatively high and are also a concern. The exc~ssiye l()aciings at the
influent structure are causing an increase in sludge production and electrical
consumption at the facility. Our continued efforts to reduce the influent loadings
and oils and greases should help in reducing this concern.
3 .1 PRETREATMENT
Pretreatment activities for the m()nthoLF~1:>,rtlary include:
There were no NOV's issued for the month of February.
fi
Intermittent yearly industrial sampling of
Philadelphia Quartz and Wyandot was
performed. IWR was permitted to resume
their discharge, to the city sewer system.
IWR will be required to meet a 3.50 lbs of
chemical oxygen demand (COD) per day
and to increase theirclaily monitoring of
MBAS until d~emeclntrf~s~ary by the city.
An attempt to inspect Custom Plating
failed due to the business doors were
closed. Continued attempts resulted in the
same.
The Annual Report to the state was finalized and sent out on February 24,
1998.
Jeffersonville Wastewater Treatment Facility
Monthl 0 erations Report
4.0 PREVENTIVE AND UNSCHEDULED MAINTENANCE
Preventive maintenance was performed on all equipment as scheduled in
February. There were 25 unscheduled maintenance tasks performed. All
were minor repairs except for:
~
Replaced belt on #2 Sludge Press.
Replaced clack valve on # 1 Penn Valley pump.
Replaced motor for speed control
on #2 Sludge Press. I
Flow meters for Return Activated ! i
Sludge and Waste Line
were calibrated by Tech Line Co.
Started the repair of replacing the
digester blower line.
~
~
~
~
A list of unscheduled maintenance work orders
is included as Attachment. E.
Maintenance and repair expenditures for the
month of February are detailed in Attachment F. Table 4.1 represents the
amount expended in February. Table 4.2 includes the same information for
repair and replacement expenditures. Attachment G contains a detail of
repair and replacement expenditures for February.
Table 4.1
MAINTENANCE & REPAIR EXPENDITURES
Time Period
Amount
Expended
Budget
(Over)
Under
February
$5,699
$4,200
($1,499)
Year-To-Date
$40,725
$42,000
$1 ,275
c
ri
Jeffersonville Wastewater Treatment Facility
Monthl 0 erations Report
Table 4.2
REPAIR & REPLACEMENT EXPENDITURES
Time Period Amount Budget (Over)
Expended Under
"' ""'~Y";'.",",",.,.,..,' . . .~I:~~~:::;~~. " ~.~..
February $4,097 $8,334
-- _.- .~ ,"
Year-To-Date $80,590 $83,340 $2,750
" ... .". ., .... .,." " "..e" e
4.3 CAPITAL IMPROVEMENT EXPENDITURES
Attachment H details expected Capital Improvement expenditures for the
contract period of May 1, 1997 through April 30, 1998.
4.4 ELECTRICAL EXPENDITURES
Table 4.4 relates to electrical expenditures for February 1998.
Table 4.4
ELECTRICAL EXPENDITURES
Time Period Amount Budget (Over)
Expended Under
.~.... .,,,,,;,' .-......". .."
February 17,682 $15,918 ($1,764)
(estimated) .,
",,"
Year-to-Date 175,870 $159,180 . ($16,6901)
(estimated)
~_ _ _~""~"______ _O_''''.H__............ "~-~.."-"'-~~'f"--"'.,.--------'" ,,_.'''',''''-'','","'''1 '-""," , ; ..
r
l
r
l
Jeffersonville Wastewater Treatment Facility
Monthl 0 erations Report
5. 0 FACILITY SAFETY & TRAINING
A safety inspection was conducted. on Fepll.@ry 27, 1998. The rating was a 98%.
The deficiencies reported were:
~ Paint thinner left out on work bench in the
Maintenance Garage.
Safety training for the month was conducted by the
Susan Tomasallo on First Aid & .CPB,... A. SOpy of
the Safety Inspection report is included as
Attachment I.
6.0 SEWER COLLECTION SYSTEM
",G
-
During the month there were 16 sewer calls. Thecalls\V~rerelate~..t()~rH~f()ll()wing:
r
r
t
r
t,
I,
l .
~ Eight were related to residential problems.
~ Two were due to odors
~ Five were due blockages in the City's main line.
~ One was caused by roots.
Collections system personnel are still working in the Meadows Subdivision checking
homes for illegal sump pumps connections. They
have completed cleaning all troubled sewer spots
around the city. At Crums 2 lift station we pulled
and unstopped No. 1 pump. The crew also
helped the City to clean snow off of the streets.
Table 6.1, on the next page, details the data on
February's sewer projects.
r'
i(
;
JeffersomJille Wastewater Treatment Facility
Monthlv Operations Report
ont Iy 0 ectlOn Analysis Re lort
Project
,
January
Year to Date
Sanitary Sewer Cleaned / Feet
Storm Sewer Cleaned / Feet
15,755
1,360
163,957
4,178
,
Catchbasins Cleaned
".
Grate Tops = 220
Vactored = 11
Grate Tops = 1865
Vactored = 63
-~
~ ~ _, ..,..~N_. _'"NO ,"'""'" ,,00,". ,. '"~ .."
Catch basins Raised
o
o
13,893
..
52
Sewer Tap Inspections
_......._ . .~_.,~_... ~_~ ..~.. '^ .m., 'M'" ffl
...... 80 .
.' .... '.. .....3..............1
~ -'r'~ ~.= =~._: .
17
Sewer Televised / ft
Dye Testing
""".~affl~'~"'_ .,~~"~
Manhole Castings Replaced 0
Air Testing .~..~~'~.~.~~~m..~::~~]:.~..:..~:'.,:~.. . _~
_~I... ,~...'
1
31
Manholes Sealed
o
8
;"',';',.:. ',,-,.,'_,>c;'_',-,,"',,:.. ,.,.,-.;
..
Service Calls Backup Odor Main Resident Storm Related
Received Block Problem Backups
.
. .~
16 0 2 5 8 0
Locates Roots Catch Basin
75 1 0
,!.. .'"....".','. , """. ",J
r
L
,.....
I :
r
!
\
r
l J
n
lJ
rn
lL
r
r
L
r
I
\
Jeffersonville Wastewater Treatment Facility
Monthl 0 erations Report
ATTACHMENTS -
A Time Series Plots - CBOD & TSS
B Time Series Plots - MLSS & SVI
C Flows & Loadings Report May 1994 through February 1998
D Septic Haulers Report
E Unscheduled Maintenance Work Orders
F Maintenance & Repair Expenditures
G Repair & Replacement Expenditures
H Capital improvement expenditures
I Safety Inspection Report
Attachment A
Time Series Plots
CBOD & TSS
n
{ ~
r"'""
(""'!'
,.....,...,
i
f
I"']"
}j
rl
w,o
r
ij""
r
iii
\1
(L~,
r
r
.~
.:.=
.....c
U
~
~
....
=
v
S~
~~
1-1..........
~O
~O
....~
~U
v ....
.... =
{;/.} v
~ =
~e
V~
.,.....
.,.....
.....c
~
o
(/.)
1-1
~
~
V
~
VJ
VJ
f-
....
's
1-<
~
I
o
o
co
U
....
.~
Q)"
~
I
VJ
VJ
f-
....
c:
~
E
i:.lJ
I
o
o
co
u
....
c:
Q)
;:;:l
E
i:.lJ
I
o
It'l
o
""
o
M
o
C'l
o
-<
00
C'l
;;. ~
~)''::
~ E
::: ~
S r:-
:::0
~ ...
~ ~
"'= 1:::
~ .~
"':::: :::
~ ..
E~
" -
8'1::
~
'"
:::
~
"..
~
t-..
C'l
\0
C'l
It'l
C'l
""
C'l
M
C'l
C'l
C'l
C'l
o
C'l
'"
00
t-..
\0
co
0\
0\
~
It'l
-<
c-
~
:;j
lo--(
..CJ
(L)
~
""
-<
M
C'l
-<
-<
-<
o
-<
'"
00
t-..
\0
It'l
""
M
C'l
o
Attacltment B
Time Series Plots
MLSS & SVI
rr:
!L,
tT
'I
L
[
rr
!I
[
[
r
"~ '
[
r
~
u ;
r
li
~
i.
~
...
-
...
~
~ ~
= =
~ ~ .-.
e 0 rJ)
i &~
~~~
~ "= --
~ ~ trJ
.....~"'O
= ... .~
~~o
~=rJ)
trJ ~
= .. "'0
>~
~~~
~ ~ =
= < ~
~ ~
= trJ
~ =
~ rJ)
~
~
~
IZl
IZl
f-<
....
's
:3
.~
(j)
~
Cl
I
~
IZl
IZl
....J
:E
I
o
o
l/"')
"<t'
8
o
"<t'
o
o
l/"')
M
o
o
o
M
8
l/"')
C'l
o
o
o
C'l
o
o
l/"')
o
o
o
......
o
o
l/')
~
C'l
~,~
~ ~
~ .,
's r:-
~c3
~ -:::
"'" >l
"'= =:
~ ~
"'= ~
~ '"
::: ~
" -
01'l..~
~
"
=:
~
~
'S:
~
\0
C'l
l/')
C'l
"<t'
C'l
M
C'l
C'l
C'l
......
C'l
o
C'l
0'\
......
00
......
~
......
\0
......
If')
......
00
0\
0\
l"'"'\
"<t<
......
~
~
;:$
~
..c
Q,)
~
M
......
C'l
......
......
......
o
......
0'\
00
~
'-0
l/')
"<t'
M
C'l
......
o
t-.. ~O~
C'l ~ ~
:: l::l
\0 Os f:<
C'l .:: c3
~ ....
l1"l ~
~ ;;;
C'l ~ ~
-.:t' ] ~
n C'l ~~
"'-
tJ M o-~
~
C'l ;;;
=:
l':
C'l '5:
C'l ~
.....
C'l
0
C'l
a 0\
.... .....
- e
....
~ 00
= i
~
..... ..... t-..
5 > .....
~ r./)
~ .-. +-' \0
01-( '6 .....
,...,.. &~ :.:s l1"l
I ClJ
i 61 ..... 00
~ ..-1 ---
l ~ ~ ..... 0\
~ <:Il -.:t' 0\
'"0 Q.J
~ Cl ~
~ ClJ "'d I
~ M ~
= .... = .....
~ =s I-(
~ ~ ~ C'l =
:: e ..... J-4
~ Q S ..... ~
.... =
~ ..... ..... ..... ~
= ,....( >
~ ~ r./)
ClJ ClJ I 0
- <
-
.5= ~
:: ~ 0\
Q
~ = 00
~ ,....(
00
I'--
ClJ
f! ~
I, \0
1
ll,
l1"l
,,-.
II -.:t'
~ ..
[ M
C'l
.....
0 0 0 0 0 0 0 0
IJj 0 l1"l 0 l1"l 0 IJj
[ M M C'l C'l ..... .....
n
\,.",
Attachment C
Flows & Loadings Report
May 1994 - February 1998
r-
r
,",,^
n
! I
t j
fT
t J
a I :
~ :
~ ,
L_
r
U,"
r
~
[:
r-,
I
L
..0
~
.~
~
~
......
=00
~~
S~
~
~ ~
~ ~
~~
~ r~
~~
~ .
~~
~~
~ ?\
~~
~
~
~
~
~
~
~~\1")O\1")O\1")O\1")\1")\1")O\1")O\1")\1")O\1")O\1")\1")\1")OMOOOO
~__l'--~_\O~OO-l'--'~OOON_'A_'~~~OOO'~-'~-
~~~M~~M~M;M:NNS~~~:~~~~~~~~
00000 000~00
-~~~~~~~~~~~~~~~~~~~~~~~~
~~M\Ol'--\o\1")_ool'--l'--\OM-\1")\1")l'--M~O'<1''<1'l'--M~\OM
OMMMM'<1''<1'MMMNNN-N-MNMNM\o\oooOOS
~~--
0.0.... 00 00
'{;; e \1") \1")
~.... 00
Cl....:l--
~
~~~~~~~~~~~~~~~~~~~~~~
0000000000000000000000000000000000000000000000
\1")\1")\1")\1")\1")~I.I'l~\1")\1")\1")\1")\1")\1")I.I'lI.l'l\1")\1")I.I'l~\1")I.I'l\1")
00000000000000000090000
~~~~~~~~~~~.~~~~~~~~~~~~
-
~
::90
-~
Cl~
o
~
MM~OO\o\1")\O'<1'0000NM~-N'<1'~0'<1'0\1")\1")8
~~oo~~8~~~~~~~g~8~~~~~~~~
M~~~~~~~~~~~~~~~~~~~~~~S
_OO-~~~~~~~~~~~~~~~~~~~~~~*O~O~~
~~OON\O\O'<1''<1'O-~\1'')N\OOONM~N'<1'--'<1'-N~
Cl\Oooool'--OOoo~_~_\1")'<1'M'<1''<1'\O\1'')\ol'--~OOOO_--
=~\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")
0.0_0000000000000000000000000
.~e~~~~~~~~~~~-~~~~~~~~~~~~~~
~_ooooooooooooooooooooooooo
O~~~~~~~~~~~~~~~~~~~~~~~~~~
-
~
::9N
_'<1'
Vl~
Vl\O
Eo-<
OO_OO\OMM~-M
~M~~~~'<1'.~~
oooo~oooo~S~~
N-M'<1''<1'OON\1'')~-~O~~;:;
l'--_~N'<1'M\OM'<1'-Noo
\1") N \1") 00 N M ~ N '<1'N N '<1' ~-.lI'l
v)~~~~~v)~~~oooo:::~:!
o *00 *00 *00
~~~~!~~!~!~~~!~~~~~~!~~~a~~
Oool'--l'--\Ol'--l'--l'--OOl'--\1")\1")\1")\o\1")'<1'\O'<1'~~\Ooo\O_--
~ ~
0.0 ....
'{;; e
~ ....
Cl~
=
~~~~~NN~~~~~~~~~~~NN~N~N~
\1")~\1")~~v)v)\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")\1")v)~\1")v)\1")~\1")
-
Cl
~
-
~
-
~
O'<1'OO\1")__~~_Nl'--M\O~-NMl'--'<1'N~OO\1")\1")l'--
\1")~~~~l'--O_~~oo\O~l'--MNMOO\ONNN~OO-
~MMMMM~~MNNNMNNMNNNM~M\1")\1")OO
'<1'
.s ~ ~
= - =
o ...... :l
:E ~-
:E
\0
~
~~~
ZCl
...c::_.....
u .... ::;'
~ l-< '"
~ ~:E
\1")
~
~o.o~t~~~-5
.a~~OZCl;~
-
...c::
u:C ~~~~~t
~~:E.a.a<~O
,.Q
~
~~
~
-
~ .~
~~
.s e.
~0
, "':l -
:: ::
<:l ~
] ~
l:: ~
8-~
S!
::
.,
lO
::
l2
';:
~
....
---
~
.
~
n
I I
l(,.;
f'T1
~
,
r
L
[
r
~
t
.€
:;:
~
~
,..
=:00
~~
s~
~ ~
~ e
~~
~~
~ I
~
~~
~~
~ ~
:;:~
;:.;...<
~
~
r:
~
~
~
~,~
] ~
.s e.
~o
11 ::
':I ~
] ~
E ':I
~~
E
0:
~
0:
12
~
1~~~~~~;~~~~~2~~~~~~~;~
~
~~~~~~~~~~~~~~~~~~~~
oo~~oS~~~~oo~~~~~~oooo~~
oo~~oo_____~~oo--~~~~oooo
~~~~~~~~~~~~~~~~~~~~~
000000000000000000000000000000000000000000
~~~~~~~~~~~~~~~~~~~~~
000000000000000000000
~~~~~~~~~~~~~~~~~~~.~~
-
CI.l
~~~~oo-~~~~~g~~~~~~~g~~
~~~~~~~q~~~~~~~~~~~~oo~
~o .0 . .-_~~MO . .~-OOO
O_~-~OO------~OO----_OOOOoo
CQ
~~~~~~~~~~~~~~~~~~~~~
~~M~O~~~~~~~~O~OOOO_~~-OO~
_ ~~--~OM~~~~~OOMM-~~ ~O
O--------~~----- _00 -~
=~~~~~~~~~~~~~~~~~~~~~~
~-OOOOOOOOOOOOOOOOOOO,OO
-r;; e ........c ....-( ,......oj ..... ~ ~ .~ ~ ,.;.;..( ,...... ,....c; ~ ..-: ~ ,......( ~ --< .,..;o.;.;c' ,......,..'..~ ,;...;..(
~.~OOOOOOOOOOOOOOOOOOOOO
~~..-:~,......(..-:~..-:..-:--<........c..-:-~~"-:~~"-:"-:,......("-:~"-:
C\I
-
]~~OO~~-~-~~~~~~~ ~ 0
_~~~~~~~OO~OOOO~~~~~M~~~~
-~~-~q~~~~~~~~~~-~~~~~
~~~~~~~~~~~~~~~~~~OO~S~
Eo-<
=~
'#. .;; 0
~-
0-
~ ~ ~ ~oo ~Oo ~oo ~Oo ~oO
~~~~~~OO~~OO-~~~~~~~~
~~~~~_O-OO~MM~~~M--~
OO~~OO~__-~---OOOO~~~OO~-
= ~
'1~~~~~~~~~~~~~~~~~~~~~
~-~~~~~~~~~~~~~~~~~~~~~
o.....l
6
Co:)
~~
- .
~~
o
-
~
~M~~O~~~~M~~~M~O-M--
M~~~OO~~OO~~~OM~~~~~~~
~M~~~~~~S~~~~~MMM~~~
~
~O ~-S-~e.t ~ ~~
:e.a--<CZlOZO~
--
.c
,.Q~:C: ~~-S-~Q..t ~
~~~~.a__<~OZ
ao
~
~~,.Q
I""\-~
i-I=~
ell
--
Attachment D
Septic Haulers Report
May 1997 - February 1998
r--
,......,
\
f
,......
,
,
~ ,
,
,....,
:
Li
r
i
-..--~.,;
r
, i:
tl.
rr
1'1
L
rr-
~
[
r
SEPTIC HAULERS REPORT
February 1998
, ..."".' ,:e,':,',":,' .... .<," ,'";,,
,
Loads Delivered To Treatment Facility
..
Hauler February Hauler Total (YTD)
,- .,.,' .....
Rumpke of Indiana 7 71
--
TOTAL 7 71
- ,
..... .. ..
'. ". .""."""',
, ,
Gallons Delivered To Treatment Facility
~:n "
Hauler February Hauler Total (YTD)
.
Rumpke of In~~;~::~~"I".~,"_""'=~"="~.."""~'. "'i:i~~', "'....,,,'",."".'.. '.ro,'. ~,",,"', "~l ",.>
<",'""
- 86,800
..-- , " r'" '. 0"'_ , -
TOTAL 18,600 86,800
,
cC'. ."" ....,. ..,. :.. ,::.. ,y',,:,;', ''';'.''
,,......
,......
i
I
I
I
,.
Attachment E
Unscheduled Maintenance Work ()rders
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
3
Page
I Close Date:
. W.O. #:9800128
... - .. --., ,.
I
Task #:
Originator:
Phone:
Oown Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 2/4/98
Completion Date: 2/18/98
Delay Description:
Equipment #: 1CL2BUILDING1
Description: CL2 BUILDING
Comments: CLEANED UP GARAGE, GRIT BUILDING, CL2/S02 BUILDING
l:mployee# Name Date ...
. 2/18/Q8
r
CLEAN UP BUILDINGS
r
t.
0,00
6.00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
r
il
L.
r
L
Down Time:
r-
"
"
II
~-~-;>'
MAJ
MICHAEL ARMS JR.
PROJECT
1.00
MAJ
6,00
2/4/98
10:49:32
2/4/98
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 11.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
Reg Aoul"s OTHours
r
t..
Equipment #: 1GARAGE1
Description: GARAGE BUILDING
Comments:
Down Time:
6.00
Down Time:
Task #:
O~iginator:
Phone:
Down Time:
E'!lp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/7/98
Completion Date: 1/7/98
Delay Description:
Equipment #: 1 RASST A TION
Description: RAS PUMP STATION
Comments: RESET PADDLES ON PIPE ADJUSTED METER. NO CHANGE.
Equipment #: 1GRITBUILDING1
Description: GRIT BUILDING
Cpmments:
I CloseDat~: 2/18/98 .
I
TRY TO RESET RAS METER
W~O~#:98bo133 .
0,00
1,00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
Down Time:
Employee #
OM
JT
Name
DANNY MILES
JOE T ACKET
PROJECT
1.00
OM
1,00
1/7/98
10:49:01
Date
1/7/98
1/7/98
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 30.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
Reg Hours
OT Hours
0,50
0.50
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
Page
7
I Close Date: 2/18/98' W~O. #:980()13()
REPLACE BRUSHES ON # 2 BAR SCREEN
Task #:
. Originator.
Phone:
Do:.vn Time:
Emp. Hours:
Vendor Hours:
I
Request Date:
Sched Start Date: 1/20/98
Completion Date: 1/20/98
De/ay Description:
,
Eq'uipment #:
Description:
Comments:
,
Employee #
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
REPAIR
1.00
0,00
6,00
0,00
DM
6.00
1/20/98
10:49:19
1BARSCREEN2
BARSCREEN #2
REPLACED UPPER BRUSHES ON #2 BAR SCREEN. 8 IN ALL
Down Time:
Name
Date"
'I
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 21.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
. R.eg Hours 'OTHourS
DM
JT
DANNY MILES
JOE TACKET
1/20/98
1/20/98
3.00
3,00
I Close Date: . 2/18/98
UN'STOP CL2 DIFUSSERS
W.O. #: 9800131
I
0.00
4,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
REPAIR
1.00
Task #:
,
Originator:
phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
SC,hed Start Date: 1/18/98
Completion Date: 1/18/98
Delay Description:
Equipment #: 1CHLORINATOR1
Description: V-NOTCH CHLORINATOR #1
Comments: DRAINED AND UNSTOPPED DIFUSSER IN CONTACT BOX.
DM
4,00
1/18/98
10:49:13
Down Time:
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 23.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
r Employee # Name Date Reg Hours OT HourS
~ OM DANNY MILES 1/18/98 2.00
Ib..~
JT JOE T ACKET 2117/98 2.00
KW KEVIN WRIGHT
n
L
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
Page
8
I Close Date:
W.O. #:<98001$2 .
............>1
Task #:
Originator:
Phone:
I
Down Time:
Emp. Hours:
Vendor Hours:
I
Request Date:
Sched Start Date: 1/12/98
Completion Date: 1/12/98
Delay Description:
Equipment #: 1 SAMPLERFINAL 1
Description: FINAL EFFLUENT SAMPLER
Comments: REPLACED PUMP IN RAW SAMPLER, FROM OLD SAMPLER THAT NEEDED REPAIRS.
2/18/98
REPLACE PUMP IN RAW SAMPLER
0,00
5,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
Down Time:
i. ., ,',''''''''
Employee #
Name
OM
JT
DANNY MILES
JOE T ACKET
REPAIR
1,00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
27.00
N
Reg Hours ..... ....OtHours
REPAIR
1,00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
OM
5,00
1/12/98
10:49:07
Date.
1/12/98
1/12/98
2.50
2.50
Task #:
Originator:
Phone:
Down Time:
E~p. Hours:
Vendor Hours:
Request Date:
SC,hed Start Date: 1/8/98
Completion Date: 1/8/98
Delay Description:
Equipment #: 1 BFPFEED2 Down Time:
D4!scription : BELT FILTER PRESS SLUDGE FEED PUMP #2
Comments: PUT NEW BELT ONTO #4 PENN VALLEY PUMP REEVES DRIVE UNIT, $53,00
I Close Date: ..... 2/1$/98 W.O. #: M00134
R~PLACE BELT ON. PENN VALLEY PUMP
0,00
1,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
:r-',
il
!i
OM
1.00
1/8/98
10:48:55
"pn..............
LL..l1J
29.00
N
,- Employee # Name Date Reg Hours OT Hours
H
:j
H OM DANNY MILES 1/8/98 1.00
,
n
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
9
Page
I Close Date:
W.O. #:9800135
...........>/
2/18/98
CHECK OUT # 2 PUMP FOR PROBLEMS
n
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/6/98
Completion Date: 1/22/98
Del~y Description:
Equipment #: 5RIVERPORT II
Description:
Comments:
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
0.00
12.00
0.00
Down Time:
REPAIR
1,00
KJ
12,00
1/22/98
10:48:49
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
31.00
N
PULLED # 2 PUMP BEARING AND IMPELLER BAD, SENT TO DERBY CITY ELECTRIC TO FIX,
SPENCERS COATED IMPELLER, CHEMTRUSION TO PAY FOR REPAIRS BE CAUSE OF BEADS THEY
DISCHARGED INTO SEWERS.
Employee'#
dG
KJ
MA
Name
DONNIE GRIFFIN
KENNETH S. JAMES
MIKE ARMS
,
I Clos~ Date:
2/18/98
W.O.#:9800136 '..
CHECK OUT PUMPS AND CONTROLS
Task #:
O~ginator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
I
Request Date:
Sched Start Date: 1/5/98
r Completion Date: 1/6/98
t! Delay Description:
Equipment #: 5POWERHOUSE
r
..1,,' Description:
[ Comments:
R
L
Wo Type:
Priority:
Ext.:
A!?signed By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
0,00
10.50
0,00
Down Time:
Date
. Reg HourS
4.00
4,00
4,00
oTHours.
1/22/98
1/22/98
1/22/98
REPAIR
1,00
KJ
10.50
1/6/98
10:48:43
Date
I
"
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
32,00
N
#1 MOTOR BAD REPLACED, #2 PUMP STOPPED UP, CLEANED OUT, TIGHTEN UP MOTOR AND
BEARING PLATE.
Employee #
Name
DG
KJ
MA
DONNIE GRIFFIN
KENNETH S, JAMES
MIKE ARMS
Reg Hours
OT Hours
1/5/98
1/5/98
1/5/98
3,50
3.50
3.50
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
Page
10
I
::/
I Close Date:
2/18/98
w.oA#:' 98Od131
CHECK OUT ( RTU) AT 10TH STREET STATION
!
REPAIR
1.00
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/13/98
Completion Date: 1/14/98
Del~y Description:
Equipment #: 5TENTH ST.
Description:
Comments:
,
n
t .I
n
0,00
8,00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
1/14/98
10:48:37
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
26,00
N
MA
8.00
Down Time:
MIKE TRYED TO FIX RTU BUT HAD TO CALL CONTROL TOUCH FOR HELP FOUND PROBLEM IN
PROGRAM AND IN RADIO INTERFERANCE.
~mployee#
MA
Name
Pate
MIKE ARMS
1/13/98
Re.g 1-J()~rS ....OTHoul'l5
8.00
CHECK OUT LOUISE ST STATION
. 2/18/98
..W.O~j:98b()138
i'l""",
II
c
0,00
2,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
REPAIR
1,00
I Close Daba: .
"'"?1
.....::..::::.
Task #:
Originator:
Phone:
Down Time:
Ell1p. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/2/98
,
Completion Date: 1/2/98
Delay Description:
Equipment #: 5LOUISE ST.
Description :
Comments:
r-
MA
2.00
1/2/98
10:48:31
Down Time:
PULLED #2 PUMP STOPPED UP WITH RAGS,
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 33.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
Employee # Name Date Reg Hours OT HourS
I '
HH HERSHEL HAMBY 1/2198 1.00
MA MIKE ARMS 1/2/98 1.00
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
Page
11
I
I Close Date:
2/18/98
W.O. #:. 9800140 .
CHECK OUT SUMP PUMP AND SEWAGE PUMPS
,
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
R~quest Date:
Sched start Date: 1/12/98
Completion Date: 1/12/98
~Iay De,scription:
Equipment #: 5SPRING STREET
~scription :
Comments: CLEANED OUT WET WELL WITH VACTOR, UNSTOPPED SUMP PUMP LINE.
Employee # .... Name .... Date Reg HOlJrj
rr,
lie I ,
HH
MA
RL
m
t I I Close Date: .
0.00
4,50
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
REPAIR
1,00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
27.00
N
MA
4.50
1/12/98
10:48:17
Down Time:
......./()THOlJrj
HERSHEL HAMBY
MIKE ARMS
ROBERT LUNEY
1/12/98
1/12/98
1/12/98
1.50
1.50
1.50
, ,., , ,.. I
:......::..-:.:::::.::;:
Ta,sk #:
Originator:
Phone:
DOwn Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/12/98
Completion Date: 1/12/98
Delay Description:
Equipment #: 5CRUMS LANE III
Description:
Comments:
CHECK CRUMS #3
. ...2/1.8/98
... ",-.. ..,-,.
W.O.f#:980Q142
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
27,00
N
0,00
4,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
REPAIR
1,00
Employee #
#2 PUMP PULLING HIGH AMPS, PULLED AND CLEANED OUT WET WELL, OK NOW.
Reg Hours
OT HourS
DG
MA
fi
r
,
l
MA
4,00
1/12/98
10:48:05
Down Time:
Name
Date
DONNIE GRIFFIN
MIKE ARMS
1/12/98
1/12/98
2,00
2,00
3{9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
Page
12
I Close Date:
.W.0.#:9800143
...1
2/18/98...
CHECK MIDDLE SCHOOL STATION
,
Task #:
Originator:
I
Phone:
D6wn Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/15/98
Completion Date: 1/15/98
Delay Description:
Equipment #: 5MIDDLE SCHOOL
Description:
cOmments:
0,00
1,25
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
Down Time:
#2 PUMP AIR BOUND OFF FLOAT BAD REPLACED,
Employee #
MA
Name
MIKE ARMS
I Close Date: 2/18/98
m I
~Ii CHECK OUT MAGNOLiA STATION
tl
REPAIR
1,00
MA
1.25
1/15/98
10:47:59
Date
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 24.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
Reg Hours
1/15/98
1.25
OTHourS
W.O. #: >9800144
.1
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/22/98
cOmpletion Date: 1/22/98
Delay Description:
Equipment #: 5MAGNOLlA ST
~scription :
Comments:
0.00
3,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
Down Time:
REPAIR
1.00
KJ
3,00
1/22198
10:47:52
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
19.00
N
f:
.',
.
'1l"",,...'
Employee #
#1 PUMP STOPPED UP FULL OF ROOTS AND GRAGS, CLEANED OUT.
Nartle .. Date
Reg Hours
OT H()ijri;;
,
DG
KJ
MA
DONNIE GRIFFIN
KENNETH S. JAMES
MIKE ARMS
r
r
1/22/98
1/22/98
1/22/98
1,00
1.00
1,00
fll
, .;
m
t! j
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
13
Page
I Close Date:
w.o. #:9M0146
I
2/18/98
CHECK POWER HOUSE STATION
-
W
! @!
Task #:
Originator:
Phone:
Dbwn Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/26/98
Completion Date: 1/26/98
~Iay Description:
Equipment #: 5POWERHOUSE
Description :
Comments:
Down Time:
0,00
3,50
0.00
WoType:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
f"r':
/i
;1
REPAIR
1.00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
N
17,00
MA
3,50
1/26/98
10:47:35
#2 PUMP MAKING LOTS OF NOISES AND VIBRATING, CHECK VALVE HAD A BIG ROCK IN IT
UNSTOPPED CHECK VALVE.
Employee #
DG
MA
m I<C,lose Date:
II '
NalllE!
DONNIE GRIFFIN
MIKE ARMS
2f18f98
W.O.#: '9800147
CHECK OUT HEATER AT SPRING ST STATION
Task #:
I
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
~i, Sched Start Date: 12/11/97
1.,L....'"
Completion Date: 1/28/98
De,lay Description:
fJ
~ Equipment #: 5SPRING STREET
Description:
Comments:
0,00
4.00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
m
cate
" Reg Hours
"or Hours
1/26/98
1/26/98
1.75
1,75
pi
REPAIR
1.00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
N
49.00
MA
4,00
1/28f98
10:47:28
Down Time:
CHECK OUT HEATER ON 12/11/97 AND ORDERED PARTS,
1/20/98 PUT IN HEATER PARTS, HEATER STILL NOT WORKING ORERED MORE PARTS,
1/28/98 FIXED HEATER WORKING OK NOW.
G
~
Employee #
Name
I
MA
MIKE ARMS
1T"""
i ;
r
~
j
Date'
Reg Hours
OT Hours
1/28/98
4.00
m
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
14
Page
I Close Date:
W.O. #:9800148
2/18/98
CHECK OUT HOUR METER AT COLONAL STATION
m
! ~I;
Task #:
Originator:
I .
Phone:
D~wn Time: 0.00
Emp. Hours: 1.00
Vendor Hours: 0,00
Request Date:
Sched Start Date: 1/30/98
Completion Date: 1/30/98
~Iay Description:
,
Wo Type: REPAIR
Priority: 1.00
Ext.:
Assigned By:
Assigned To: MA
Total Labor Hrs: 1.00
Request Time:
Sched Finish Date: 1/30/98
Completion Time: 10:47:22
Equipment #:
~scription :
Comments:
Employee.'
MA
5COLONIAL PARK
Down Time:
PUT NEW HOUR METER IN FOR PUMP # 1 PUMP.
Name ... Date.
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 13.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
1/30/98
Regl-lou~ .....OTHourS
1.00
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Ve'ndor Hours:
Request Date:
Sched Start Date: 1/29/98
Completion Date: 1/29/98
Delay Description:
Equipment #: JET TRUCK
Description : FOOTAGE CLEANED
Comments: TRYED TO TV MAIN BUT CAMEAA NOT WORKING RIGHT. SENT CAMERA OFF TO BE FIX.
CLEANED 400' FEET OF SEWER MAIN,
MIKE ARMS
I
I Close Pate:
2/18/96.. ..
W.O. #: 9800150
TV CENTER ST FOR RICE CONSTRUCTION
fl
1
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
TV
1,00
0.00
24.00
0.00
KJ
24,00
1/29/98
10:47:01
Down Time:
r
~'I
~!
Employee #
I ... ..,
00
KJ
MAJ
1/29/98
1/29/98
1/29/98
Name
Date"
DONNIE GRIFFIN
KENNETH S. JAMES
MICHAEL ARMS JR.
I
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
14.00
N
Reg HourS ..
8,00
8,00
8.00
OT Hours
Equipment #: TELEIVISING
Description: SEWER LINES TV
Comments:
Down Time:
rr-
~I ;
~I,
r
ii
H
3/9/98
!
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
Page
15
W.O. #: .9800151
I Close Date:
2/18/9S
,
TV RIDDLE ST LOOK FOR TAP FOR SONIC.
Task #:
Opginator.
P~one:
Down Time:
Emp.,Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/23/98
Completion Date: 1/23/98
DEilay Description:
Equipment #: JET TRUCK
Description: FOOTAGE CLEANED
cOmments: JET CLEANED 1000' FEET OF SEWER MAIN ON RIDDLE AND SPRING ST.
TV 386' FEET OF MAIN ON RIDDLE ST, TV CAMERA GOT STUCK IN MAIN HAD A HARD TIME GETTING
IT OUT, SPENT ALL DAY ON THIS JOB,
Employee #
DG
HH
KJ
MA
0,00
32.00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
N
TV
1.00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
18,00
KJ
32.00
1/23/98
10:46:54
Down Time:
Name ..
bate
(jTHoul'S
DONNIE GRIFFIN
HERSHEL HAMBY
KENNETH S, JAMES
MIKE ARMS
1/23/98
1/23/98
1/23/98
1/23/98
RegHoul'S ...
8,00
8.00
8,00
8.00
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/22/98
Completion Date: 1/22/98
Delay Description:
Equipment #: 5MAGNOLlA ST
Description :
Comments:
m
Equipment#:
~scription :
Comments:
I Close Date:
!
CHECK MAGNOLIA ST
~
"I
f!
rr.
~I
\j,.,
Eimployee#
KJ
MA
rr
fl
'I
~~;
TELEIVISING
SEWER LINES TV
Down Time:
2/18/98
.71
.....,.... .
W.O.#: ...$800152
0.00
2.00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
REPAIR
1,00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 19.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
KJ
2,00
1/22/98
10:46:48
Down Time:
#1 PUMP STOPPED UP WITH RAGS, CLEANED OUT.
Name Date
Reg Hours
OT Hours
KENNETH S, JAMES
MIKE ARMS
1/22/98
1/22/98
1,00
1.00
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
16
Page
I Close Date:'.
2/18/98
W.O. #:9S0015.3 .
....1
Task #:
Originator:
I
Phone:
Down Time;
Emp. Hours:
Vendor Hours:
I
Request Date;
Sched start Date: 1/7/98
Completion Date; 1/7/98
~Iay Description:
Equipment#: CATCHBASIN
Description: GENERAL
Comments: CLEANED CATCH BASIN AROUND CITY, VACTORED 50' FEET OF SEWER MAIN,
I
Employee # .. Name. [)ate
CLEAN CATCH BASIN IN CITY
0.00
16,00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
Down Time:
m
pG
KJ
DONNIE GRIFFIN
KENNETH S. JAMES
CB
1.00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
N
30.00
KJ
16.00
1/7/98
10:46:40
.. RegHou.-$ ...
OT Houts
1/7/98
1/7/98
8.00
8.00
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/6/98
Completion Date: 1/6/98
Delay Description:
Equipment #: JET TRUCK
Description: FOOTAGE CLEANED
Comments: CLEANED 400' FEET OF SEWER MAIN ON SHARON ST.
.im
t. .
j ~i-.:
Equipment #: JET TRUCK Down Time:
~scription: FOOTAGE CLEANED
Comments:
I Close nate: 2/18/98 W~():#:/ge06154
I
CHECK SEWER MAIN ON SHARON ST
0,00
6,00
0,00
Wo Type;
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time;
. Sched Finish Date:
Completion Time:
tr
rl ~
H
\,L_
Down Time:
Employee #
Name
n:
tJ
I
DG
KJ
MA
DONNIE GRIFFIN
KENNETH S. JAMES
MIKE ARMS
In
;1
II
I
"
JET TRUCK
1,00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 31.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
KJ
6,00
1/6/98
10:46:33
Date
Reg Hours
... OT Hours
1/6/98
1/6/98
1/6/98
2.00
2.00
2.00
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
3/9/98
!
I Close Date:
2/18/98
W.O. #: 9800149
T~Y TO PULL GATE OUT OF MAGNOLIA WET WELL
i
Task #:
O~ginator:
Phone:
Oown Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/30/98
Completion Date: 1/30/98
~Iay Description:
Equipment #: 5MAGNOLlA ST
~scription :
Comments: PULLED GATE OUT OF WET WELL,
0,00
7.50
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
Down Time:
i
Employeef#
Name.
DG
HH
KJ
m I Close Date:.'".
lJj .
DONNIE GRIFFIN
HERSHEL HAMBY
KENNETH S. JAMES
2/18/98
. W.O.#: .9800156
CHECK MH IN DITCH LINE IN UTICA TO SEE IF ANY LIDS ARE OFF.
0,00
4,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
ITl
"II
ii i
ffl
tL
Down Time:
DG
KJ
DONNIE GRIFFIN
KENNETH S. JAMES
r
r
I
PROJECT
1.00
KJ
7.50
1/30/98
10:47:09
Date
Page
4
I
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 13,00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
Reg HOtJrS '.OT!-I()tJrS
1/30/98
1/30/98
1/30/98
PROJECT
1,00
KJ
4,00
1/8/98
10:46:18
2,50
2.50
2,50
1
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 29,00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
Reg Hours
OT Hours
Task #:
I
Originator:
Ph,one:
D~wn Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sc~ed Start Date: 1/8/98
Completion Date: 1/8/98
Delay Description:
Equipment #: Inspection
Description: Sewer inspections
Comments: CHECKED MHs IN DITCH LINE IN UTICA ALL WERE OK,
Employee # Name Date
I
1/8/98
1/8/98
2.00
2.00
IT":
;11
*.1;
319198
I
I ylose Date:
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
2118198
W.O. 'II: 9800155
Page
17
TAKE BELT OF OF #2 PRESS IN SLUDGE BUILDING OND PUT oN NEW ONE.
I
I
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 2/9/98
Completion Date: 2/9/98
oelay Description:
I
Equipment #: 1 BFP2
Description : BELT FILTER PRESS #2
Comments: TOOK OFF BELT PUT ON NEW BELT ON #2 PRESS,
I
EmploYee '#
bG
OM
KJ
0.00
24.00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
219/98
10:46:27
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 8.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
Regl-foUrsOTHol.lts
Name
Date.
~18/~8
W.O. #:9800157
REPAIR
1,00
KJ
24.00
Down Time:
DONNIE GRIFFIN
DANNY MILES
KENNETH S, JAMES
219/98
219/98
2/9/98
8,00
8.00
8,00
I Close Date:
I
CHECK ALL STATIONS THAT HAD ARLAMS LAST NIGHT
Task #:
I
Originator.
Phone:
I
Do,wn Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 118/98
Completion Date: 118/98
Delay Description:
Eq'uipment #: 5ARTIC SPRINGS
De'scription :
Comments:
0.00
4,00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
118/98
10:46:11
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
29,00
N
REPAIR
1.00
KJ
4,00
Down Time:
CHECK ALL STATION THAT HAD ALARMS LAST NIGHT ALL OK.
Employee # Narne Date Reg Hours OT Hours
DG DONNIE GRIFFIN 1/8/98 2,00
KJ KENNETH S. JAMES 1/8/98 2.00
m
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
3/9/98
I
I Close Date:
2/18/98
TRY TO FIND WATER LINE FOR DOG POUND
W.O. #:9S00158
m
U~
i
I
Task #:
Orginator:
Phone:
Dbwn Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 1/20/98
C<;,mpletion Date: 1/20/98
~Iay Description:
Equipment fl.: Inspection
Description: Sewer inspections
Cbmments: LOCATED WATER LINE,
i . . . '
Employee' .'. Name .....
0.00
4.00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
Down Time:
PROJECT
1.00
BOB MILLER
KJ
4.00
1/20/98
10:46:03
Date ..
DG
KJ
DONNIE GRIFFIN
KENNETH S, JAMES
1/20/98
1/20/98
2,00
2,00
otHours
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 21.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
.. RegHo~l-$ ......
Page
5
..../
I CloseDat~: 2/18/98 W.O. #: 9800160
I
T~Y TO PUT UP HOIST AT SPRING ST STATION
ill
Task fl.:
i
Originator:
Phone:
Down Time:
E~p. Hours:
V~ndor Hours:
Request Date:
SC,hed Start Date: 1/20/98
Cqmpletion Date: 1/20/98
Delay Description:
Equipment fl.: 5SPRING STREET
DEiscription :
i
Comments:
0.00
6.00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
Down Time:
PROJECT
1,00
KJ
6,00
1/20/98
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
TRYED TO PUT UP HOIST BUT WHEEL WILL NOT FIT RAIL SYSTEM.
Name. Date
Employe~fI.
i.,....,
I
DG
KJ
MA
i
I
DONNIE GRIFFIN
KENNETH S. JAMES
MIKE ARMS
Reg Hours
OTHours
1/20/98
1/20/98
1/20/98
2,00
2.00
2,00
21.00
N
...,-
[J
rJ
l:
3/9/98
I
I Close Date: 2/18/98
C~EAN AND TV 21" SEWER MAIN
r
tL..
[:
'--;~ .
[J
, ,~
rl
-j
0.00
27.50
0.00
[J
[
[
Name ....
, ,',' ,",
...,.... "
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
W.O. #:9800159
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
Down Time:
TV
1,00
BOB MILLER
KJ
27,50
1/20/98
10:45:54
Oate.
Task #:
Originator:
phone:
DOwn Time:
Emp. Hours:
Vendor Hours:
I
Request Date:
SChed Start Date: 1/20/98
C~mpletion Date: 1/20/98
~Iay Description:
Equipment #: JET TRUCK
Description: FOOTAGE CLEANED
C~mments: . CLEANED AND TV 560' OF SEWER MAIN.
I
I
Employee #
PG
HH
KJ
~L
I
Equipment #:
Description:
Comments:
i
l Close Oate: .
DONNIE GRIFFIN
HERSHEL HAMBY
KENNETH S. JAMES
ROBERT LUNEY
TELEIVISING
SEWER LINES TV
u
.2/18198
~
CHECK WILSON SCHOOLS STATION
I
Task #:
Originator:
I
Phone:
I
Down Time:
Emp. Hours:
Vendor Hours:
I
Request Date:
Sched Start Date: 12/12/97
D ~~I~:~i:~~i~~: 1/12/98
Equipment #: 5WILSON SCHOOL
Description:
Comments:
0,00
3,00
0,00
Down Time:
W~OJ#:9800161'"
1/20/98
1/20/98
1/20/98
1/20/98
REPAIR
1,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To: MA
Total Labor Hrs: '3,00
Request Time:
Sched Finish Date: 12/12/97
Completion Time: 10:45:37
Down Time:
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
Reg Hours
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
WATER IN PUMP SYSTEM, CLEANED PUMP AND CLEANED PROBE.OK NOW.
Name Date Reg Hours
Employee #
HH
MA
HERSHEL HAMBY
MIKE ARMS
12/12/97
12/12/97
21,00
N
8,00
3,50
8,00
8.00
48.00
N
Page 18
I
(:,.r HQurS
...........1
1,50
1,50
OT Hours
tG
fjj
U
r
bJ.,,,:,,,
3/9/98
".' ,.:..,',:' -.,',
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
Task #:
Orginator:
Phone:
D6wn Time:
Emp. Hours:
V~ndor Hours:
Request Date:
Sched Start Date: 1/26/98
Completion Date: 1/26/98
D'1lay Description:
Equipment #: JET TRUCK
Description: FOOTAGE CLEANED
c?mments: CLEANED MAIN LINE ANDVACTORED 1350' FEET OF SEWER MAIN.
I
I
I Close Date:
2/18/98
VV.O.#:9800163
CLEAN MAIN LINE BETWEEN CHIPPEWA AND GOYNE
I
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Scheel Finish Date:
Completion Time:
[
0.00
8.00
0.00
u
[,
,j
~
tl ,:
r
i.l_
Down Time:
Employee #
JT
MAJ
JOE T ACKET
MICHAEL ARMS JR.
JET TRUCK
1.00
KW
KJ
8.0.0.
1/26/98
10.:45:18
Date
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
N
Reg Hours
1/26/98
1/26/98
4.0.0.
4.0.0.
Page 19
/
17.0.0.
OtHours
u ~~:::'ONWAl:::EAlGOOO
W.O.#:980o.164 ..
I
.. :.:'
Task #:
Originator:
Phone:
Down Time:
[J e:d;o~~~:
Request Date:
[ ~:=;~:~ :~:: ~~~:::
De'lay Description:
Equipment #: JET TRUCK
~scription : FOOTAGE CLEANED
Comments: CLEANED WALL ST REAL GOOD SEWER MAIN HAD GREASE IN IT. CLEANED 450.' FEET.
0,0.0.
4,0.0.
0.,0.0.
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
r
l
Down Time:
~mployee #
HH
RL
Name
HERSHEL HAMBY
ROBERT LUNEY
[
JET TRUCK
1.0.0.
KW
HH
4,00.
1/14/98
10.:44:59
Date
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
.25.0.0
N
Reg Hours
1/14/98
1/14/98
2,00.
2,00.
OT Hours
3/9/98
.- -. _......,..-.. ,',..,'
Work Order Histoa1/Comprehensive
E.M.C OF JEFFERSONVILLE
Page
23
ill
I
I Close Date:
2/27/98
. W.O. #:9800212
......,
fIl
ill
CHECK CLACK VALVE ON #1 PENN VALLEY PUMP
i
Task #:
Originator:
Phone:
Down Time: 0,00
Emp. Hours: 3,50
Vendor Hours: 0,00
Request Date:
SChed Start Date: 2/27/98
Completion Date: 2/27/98
DEtlay Description:
Equipment #: 1 BFPFEED1 Down Time:
Description : BELT FILTER PRESS SLUDGE FEED PUMP #1
Comments: REPLACED CLACK VALVE $70, BLEW BACK DIGESTER SLUDGE LINE CLEANED OUT VALVE. OK
! NOW.
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
REPAIR
1.00
lli
11 :18:17
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
1.00
m
ft.l"""
DM
DM
3.50
N
rr
tli
t).,,'
i:mployee# . Name. ....
OateP
Reg HOllrS
2.00
1.50
btHollrS
.... ...., ....... ---,
I
DM
J'T
DANNY MILES
JOE TACKET
2/27/98
2/27/98
in
l1 Grand Totals:
In
lJ
Down Time:
Emp. Hours:
Vendor Hours:
Total Labor Hours:
0,00
302.00
0,00
302.00 .
r;
tJ
u
[
c
c
ill
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
Page
20
2/18/98
W.O..'#:. .9800225........
. .'.1
iD
I Close Date:
-
IT:
CLEAN AND TV MAIN ON ELLIOTT
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 2/18/98
Completion Date: 2/18/98
Delay Description:
Equipment #: JET TRUCK
Description : FOOTAGE CLEANED
Comments: CLEANED AND TV LINE ON ELLIOTT ST LINE HAS LOTS OF ROOTS AT TAP,
MAIN NEEDS REPAIRED, TALKED TO BOB MILLER ABOUT PROBLEM,
CLEANED 200' TV 85'.
1iJj
m
l[J
(IJ
[J
Employ~'#./.....
DG
HH
KJ
MA
[J
0,00
8,00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
SChed Finish Date:
Completion Time:
JET TRUCK
1.00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
N
KW
KJ
8,00
1.00
11:18:18
Down Time:
Name
Date
2/18/98
2118/98
2118/98
2/18/98
Re~+f()Ursn()'rHours
2.00
2.00
2.00
2,00
DONNIE GRIFFIN
HERSHEL HAMBY
KENNETH S. JAMES
MIKE ARMS
Down Time:
[}
Equipment #: TELEIVISING
Description: SEWER LINES TV
Comments:
I Close Date: ..
.W.O.#: 91300226.
.'2/18/98 ..
...,
[J TV MAIN ON CENTER STREET SOUTH END,
Task #:
[J Originator:
Phone:
Down Time:
Ir Emp. Hours:
b Vendor Hours:
Request Date:
Sched Start Date: 2/18/98
[J Completion Date: 2/18/98
Delay Description:
Equipment #: TELEIVISING
C Description: SEWER LINES TV
Comments: TV REST OF MAIN ON CENTER ST FOR TAPS,MARKED TAPS IN GREEN FOR
LARRY RICE,
C Employee #
DG
HH
C KJ
MA
o
[,
,,~
0,00
12,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
TV
1,00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
N
KW
KJ
12,00
1,00
11:18:18
Down Time:
Name
Date
Reg Hours
OT Hours
DONNIE GRIFFIN
HERSHEL HAMBY
KENNETH S. JAMES
MIKE ARMS
3,00
3.00
3.00
3,00
2/18/98
2/18/98
2/18/98
2/18/98
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
Page
21
I Close Date:
W.o.#:9800:2:27
...~
..... .,'"
Task #:
Originator.
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 2/18/98
Completion Date: 2/18/98
Delay Description:
Equipment #: Sewer Repair
Description: Construction Crew
Comments: CLEANED ROCKS AND STICKS OUT OF MAN-HOLE, MAIN FLOWING OK NOW.
Etnployee # . Narne .. Date Regl-l9\J1"S
2/18/98
CLEAN OUT MAN-HOLE IN EASEMENT BETWEEN GOYNE AND KEWANNA
0,00
3.00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
JET TRUCK
1.00
~
KJ
3.00
11:18:18
Down Time:
o
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
1.00
N
. 01 Houl"S
DG
KJ
I
DONNIE GRIFFIN
KENNETH S, JAMES
2/18/98
2/18/98
1.50
1.50
Task #:
Originator.
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 2/19/98
Cdmpletion Date: 2/19/98
Delay Description:
Equipment #: JET TRUCK
Description: FOOTAGE CLEANED
Comments: CLEANED,FLUSHED,AND VACTORED OUT WALL STREET REAL GOOD, GOT GREASE, SLUDGE AND
PAPER TOWELS OUT OF MAIN, EVEN CLEANED LATERIAL LINE FROM DAIL YS. CLEANED 1300'
I Close Pate:2/t9/98 W.O.#: 9800228
i
CLEAN LINE ON WALL STREET REALLY
0,00
6,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
JET TRUCK
1,00
KW
MA
6.00
11:18:19
r
L
Down Time:
I
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
1.00
N
E:mployee # Name .. Date Reg Hours OTlioul"S
I
DG DONNIE GRIFFIN 2/19/98 2.00
HH HERSHEL HAMBY 2/19/98 2,00
MA MIKE ARMS 2/19/98 2.00
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
Page
22
2/23/98.
.. . W:O.#:98o0229
~
I Close Date:
CLEAN MAIN ON OHIO AVE
i
JET TRUCK
1,00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 1.00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
Sched Start Date: 2/23/98
Completion Date: 2/23/98
DehlY Description:
I.
EqUIpment #: JET TRUCK
Description: FOOTAGE CLEANED
Cotnments: CLEANED 350' OF MAIN ON OHIO ST ALL OK.
G
[j
o
n
~ I;
t,ll
Employ~#
DG
KJ
,
0.00
3,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
11:18:19
ST
KJ
3.00
Down Time:
Name
Date
Reg HOIJr$
OTHolJr$
1.50
1,50
DONNIE GRIFFIN
KENNETH S. JAMES
2/23/98
2/23/98
1
I CloseQate:d ..2/26/98 . W.O:#: 980d233
I
CLEAN CATCH-BASIN ON BRAIN, LOCUST, DOUGLAS
Task #:
Originator:
Phone:
Down Time:
m Emp. Hours:
l1 Vendor Hours:
Request Date:
,,- Sched Start Date: 2/26/98
ii, c6mpletion Date: 2/26/98
IL.! Delay Description:
Equipment #: CATCHBASIN
Description: GENERAL
cOmments: CLEANED BASIN ON LOCUST AND COURT, 100'
CLEANED BASIN ON BRAIN AND SHERMAN, 15'
CLEANED BASIN ON BRAIN AND DOUGLAS, 50'
c
Employee'
DG
0,00
2,50
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
CB
1.00
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 1,00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
ST
DG
2,50
11:18:19
Down Time:
Name.'
Date
Reg Hours
OT Hours
2.50
DONNIE GRIFFIN
2/25/98
Down Time:
Equipment #: JET TRUCK
Description: FOOTAGE CLEANED
r- Comments:
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
Page
7
... ---I
I Close Date:
WORK ON DIGGING DITCH FOR NEW BLOWER LINE.
2/24/98
W.O. #:9800231
i
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
I
Request Date:
Sched Start Date: 2/24/98
Completion Date: 2/24/98
Deh:ty Description:
EqJipment #: Sewer Repair
Description: Construction Crew
Comments: RAN BACK-HOLE DIGGING DITCH FOR NEW BLOWER LINE.
Employee I Na/TIe< Date
fl
t-J
n
( 1
KJ
, Close[)ate:
0.00
8.00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
PROJECT
1.00
KJ
KJ
8.00
11:18:19
Down Time:
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 1,00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
Reg Houi"$ ..
> OT Iiolirs
KENNETH S. JAMES
2/24/98
8.00
.2/25/98
. ........ .,--.
W.O. #: 9800232
DYE TEST LATERIAL LINE FOR 503 KEWANNA
I
I
Task #:
Originator:
Phone:
,
Down Time:
Emp. Hours:
Vehdor Hours:
Request Date:
Sched Start Date: 2/25/98
Completion Date: 2125198
r De!ay Description:
Equipment #: Inspection
r: Description: Sewer inspections
tJ c~mrnents: DYE 503 KEWANNA LATERIAL LINE FOR JOE RESHER.
Employee # .
PROJECT
1,00
0.00
1,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
11:18:19
KW
HH
1,00
DoWn Time:
Name
Date
...Gl
"::"....
Reason For Outage:
. Expense Class:
Est. Duration:
Actual Duration: 1,00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
Reg Hours OT Hours
2/25/98
1,00
HH
HERSHEL HAMBY
r-
~
t )
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
8
Page
I Close Date:
W.O.#: . 9800234
Task #:
Originator:
Phone:
Down Time:
Emp. Hours:
Vendor Hours:
Request Date:
SChed Start Date: 2/26/98
Completion Date: 2/26198
De~ay Description:
Equipment #: Sewer Repair
Description: Construction Crew
C~mments: REMOVE DIRT OFF OF DRIVE WITH BACK-HOLE, DONNIE DROVE DUMP TRUCK, PUT DIRT OVER ON
SIDE OF PLANT GENARATOR.
2/26/98
REMOVE DIRT OFF OF DRIVE BY DIGESTERS
0.00
12.00
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
11:18:19
PROJECT
1,00
KW
KJ
12.00
Down Time:
Employee #
Name.
Date
,
DG
KJ
DONNIE GRIFFIN
KENNETH S, JAMES
2/26/98
2/26/98
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
1,00
N
Reg HourS .
4.00
8,00
or Hours
..................
I CloseOate: 2/27/98
i
CHANGE OIL IN BOTH GRIT PUMPS
W.O.#:9800211..
u u I
In I
t" Ta~k #:
U Originator:
Phone:
Down Time:
I
Emp. Hours:
Vendor Hours:
Request Date:
SC,hed Start Date: 2/27/98
C6mpletion Date: .2/27/98
Delay Description:
Equipment #: 1 GRITTRAP1
~scription: JETTA GRIT TRAP
Comments: CHANGE OIL IN BOTH GRIT PUMP AND GREASE ALL OK,
Employee # . Name. Date
0,00
2,50
0.00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total Labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
PROJECT
1,00
DM
OM
2,50
11:18:17
Down Time:
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration: 1,00
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty: N
Reg HoursOTHoul'S
DM
JT
DANNY MILES
JOE T ACKET
2/27/98
2/27/98
1.75
0,75
Down Time:
Equipment #: 1 GRITTRAP2
Description: JETTA GRIT TRAP
r Comments:
[
Grand Totals:
Down Time:
Emp. Hours:
Vendor Hours:
Total Labor Hours:
0,00
145,00
0,00
145.00
3/9/98
Work Order History Comprehensive
E.M.C OF JEFFERSONVILLE
6
Page
I Close Date:
W.O. #:9800162 .
2J
....,.---
2/18/98
PUT UP STEP PLAT FORM AT MIDDLE SCHOOL.
I
I
Task #:
Originator:
Phone:
Do..lvn Time:
Emp. Hours:
Ve~dor Hours:
Request Date:
Sclled Start Date: 12/17/97
Completion Date: 2/18/98
Delay Description:
Equipment #: 5MIDDLE SCHOOL
Description:
Comments:
I
I.,.. ,........,.c., ..,_,.
employeetl
Date
BUILT A PLAT FORM AND STEPS TO GET INTO STATION, PRIMED PAINTED.
QT HQltrS
0.00
12,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
12/17/97
10:45:28
PROJECT
1.00
MA
12.00
o
n
Down Time:
Name
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
45.00
N
Reg H()urS
HH
MA
HERSHEL HAMBY
MIKE ARMS
12/17/97
12/17/97
.nU
,......---.
6,00
6.00
I Close Date: 2/23/Q8W.0. #:d9$00230
ill WO~K WITH WHITTEN ON DIGESTER BLOWER LINE REPLACEMENT BACK-HOLE
Task #:
Ori~inator:
Phohe:
Down Time:
[j Emp. Hours:
IU Vendor Hours:
Request Date:
Sched Start Date: 2/23/98
corripletion Date: 2/23/98
Delay Description:
IN Equipment #: Sewer Repair
[j Desbription: Construction Crew
d Coniments: RAN BACK-HOLE DIGGING FOR NEW BLOWER LINE WITH WHITTEN BROS,
Employee # Name Date Reg Hours
0,00
8,00
0,00
Wo Type:
Priority:
Ext.:
Assigned By:
Assigned To:
Total labor Hrs:
Request Time:
Sched Finish Date:
Completion Time:
11:18:19
PROJECT
1.00
KW
KJ
8,00
Down Time:
Reason For Outage:
Expense Class:
Est. Duration:
Actual Duration:
Response Days:
Response Hrs:
Response Mins:
Perf By Warranty:
1,00
N
OT Hours
KJ
2/23/98
8,00
KENNETH S, JAMES
r
..
-
'""""
Attachment F
Maintenance &_Repair Expenditures
Jeffersonville Wastewater Treatment Facility
Maintenance & Repair Expenditures
Page 1
P.O. Date. Vendor
Description
Amount
Jeffersonville Wastewater Treatment Facility
Maintenance & Repail'Expenditures
Page 2
P.O. Date
Vendor
Description
Amount
2/19/98 UPS SHIPPING CHARGES FOR MIKE ARMS $97.40
'2/19/98 W ALGREENS BATTERIES FOR PLANT $9.32
~ 2/19/98 ISCO, INC. . REPAIR OF INFLUENT SAMPLER MOTOR $189.00
Fi
t!.J 2/19/98 FARM BUREAlJ COPPER SULFATE FOItCOLLI:,C't'IONS $58.79
SYSTEM USE
, FARM BUREAU RAIN GUACE, SLEDGE HAMMER AND $102.53
2/19/98
SCOOPS FOR COLLECTIONS
2/19/98 UPS SHIPPING FOR PLANT $15.25
2/25/98 HARRINGTON REPLACEMENT FILTER FOR PURESS $352.65
WATER SYSTEM
2/25/98 LANG MAINTENANCE AGREEMENT ON COPY $846,00
MACHINE
2/25/98 TECH~LINE CALIBRATION OF RAS &. WAS FLOW $398.00
METER
2/25/98 ASHBROOK RUBBER SEALS FOR WASH BOXES ON $149.19
BELT PRESS
2/25/98 DERBY CITY ELECTRIC REPAIR MOTOR ON PRESS NO.2 ON $188.28
rr BELT PRESS
;1
H
u._ 2/26/98 ACE HARDWARE COTTER PINS $2.93
"'"" 2/26/98 SPENCER MACHINE REPAIR OF UNI HOIST $103.82
II :
-I
IL.,; 2/26/98 ACE HARDWARE PAINT $10.59
Total 5,698.96
[
G
r
L
r
L
r
,
,
l.
Attachment G
Repair & Replacement ExpenditlJreS
ffijl
..1'
':.t..
m
m
[,- ::
! 1,
""
m-
I:
lj,
t'l'"J'
U
m
uJ
m
fr
1.1-
~,
iL
r
r
u '
: P.O. Date
2/25/98
2/25/98
2/25/98
2/26/98
Vendor
BROWN EQUIPMENT
BROWN EQUIPMENT
SPENCER MACHINE
FALLS CITY ELECTRIC
Jeffersonville Wastewater Treatment Facility
Repair &. Replacement Expenditures
Description
(Project #97056) REPAIR OF CAMERA ON
T.V. TRUCK
(Project #97056) REPAIR OF CAMERA ON
T.V. TRUCK FOR COLLECTIONS
(Project #97059) REBUILD GRIT PUMP
AND REPLACE MECHANICAL SEAL
(Project #97049) STAINLESS STEEL
SWITCH BOXES FOR PRESS # 1& #2
Total
Page 1
Amount
$302.28
$1,163.87
$1,875.02
$756.00
4,097.17
~,
~
c ,
, ""; .....,',,,, "c'", "',;,' 'c';" '" .u >,
Lift Stations
,'.C"""",,"'" ",._,._.:,.._..:".;':"._,,,0,,,.";,"'__'-'-'--"""""., ,-.,..".".,,",..".-. I . $;~~OI .,C'. '--, ,." '..-'", ,..."".-'...' ',~
2 Replace Electrical Breakersat <=rulllS~(;lD~. I (project $2,225.24 100%
No. 97022)
.' .'. '"",'~'-' ,~
. ....... ".,
1 Sunset Mobile Home Park, Seal W etwell, Upgrade $3,500 0%
Electrical Systems, Replace Door and Roof. (project
No. 96006) (**Investigation is taking place at this
time for removal. of L.S. to gravity flow).
"'."" ......,... "'" .", .~ - .~~ .
1 Move Weather Head at Crums Lane No. 1 (project $1,500 0%
.' .... __,............"..,.........."...,...,..._...,.x...,....
No. 96007)
.. "',,, ,','
1 Painting of Interior Piping and repair of Mechanical $3,000 0%
Hoist System at Spring Street (project No. 97027)
" .."',.....,..~
1 Replace 3" portable trash pump (project No. 97014) $3,500 $1,721.14 100%
, .::, ,:t,: 'r,~. ,.$2,~~??J~~1 ~414.00
1 Replace 2" trash pump (project No. 97015) 100%
.. ~.".., ..
..
1 Repair #2 pump at Camp Powers L.S. (project No. $50,000 $1,712.52 15% I
97019)
. ., '" ." ""
1 Trouble Shoot and Repair #5 pump at 10th Street $20,000 $48,786.12 100%
Lift Station (project No. 96029)
...... ,.. ..""" ,~.._.
1 Rebuild Grit Pump and Replace Mechanical. Seal $2,000 $1,875.02 100%
(project No. 97059
-,' " "'"
1 Resurface Crums Lane II (project No. 98014) $20,000 $1,000.00 10%
.. , ,
Total Expenditures for Lift Stations $121,000 $56,508.80
'''''''','''' " ." .... .... ..." ,',. .,,'
Vehicles
, , '. .,' '" "....'..
Estimated Actual %
.
'," ," "',,".
1 Replace hose to Jet Truck & purchase new nozzles $3,000 $3,182.82 100%
(project No. 97017)
~~~~ )Control for Sewer .<=am~ra (~;~:~::-:'_'.: I_ I ~ ..-.
1 $1,200 $2,522.55 100%
.-,.~ ," ~,',~--"..,~... ,-, . .
1 Repair No. 2 pump at Ewing Lane (project No. $1,000 $1,088.54 100%
97037)
'. "
1 Replace 1986 Chevy Van (project No. 97035) $19,000 0%
~,,"" -"',,,"' _""'d ".... I -.-...--". ~24'~~I .,,".,..,',',.
Total Expenditures for Vehicles $6,793.91
...."........, ,:'1
....~.._~".,....."_."_:,,,.,"_...--" '"". c..~c??". ] _'::.' : ~...:,:::::".t1
,",,"',l.-..o.,;'.;.". "';'TOTAL $239,12204,449.'99
, "", . ',.," ;>:X] ,:,":.:"H:',";" c,1
,....,.
.......
r
'I
~
.......
t
i..~
,....,
i
i
, .
,......
r-
Attachment H
Capital Improvement Expenditures
[
r
U"
r
r
r
~,
Ii""\
L
r
tl
ri
rr
Ii
H
l.i
rr-"
fl
Ii
fi
rr-,
,1
1.i4
fP
ti ;-
n-,
'I
ti
H.
n-
t!
1996-1997 Capital Improvement Expenditures
Wastewater Treatment Facility
-,.,
Priority Description Estimated Actual %
I Repair #3 Final Clarifier Drain Valve (project $20,000 10%
No. 97005)
1 Replace Digester A ir Distribution Line $60,000 10%
(project No. 97004)
1 Fall Protection Equipment (project No. $2,500 $2, 185 100%
97036)
2 Pad for 20 yd. Roll off dumpster (project No. $2,000 $750 100%
97008)
2 Valve Actuators - 10 (project No. 96026) $35,000 0%
Total Expenditures for Wastewater Facility $119,500 $2,935
,,", ", d..
Collection System
2 6" Portable Pump (project No. 97020) $12,000 0%
2 60 KW Mercy Generator for Lift Stations $25,000 0%
(project No. 97030)
I Alarm System Upgrade Phase II (project No. $56,300 0%
97013) ,
", '" -
1 Combined Sewer Overflow Sign Posting $1,000 $1,000 100%
(project No. 97038)
"
1 Portable Flow Meter & Sampler (project No. $7,000 $ 7 ,243 100%
97032)
1 Repair Line on East Gardner Drive (project $1,500 $1,200 100%
No. 97039)
1 Install Manhole on Ridgeway Drive (project $1,000 0%
No. 97042)
1 Install Manhole on Morris Avenue (project $1,000 0%
No. 97040)
1 Repair Line on Charlestown Avenue $60,000 0%
Total Expenditures for Collection System $164,800 $9,443
f1
b Lift Stations
r $75,000
1 Sensors and flow metering for 50%
Spring Street & Mill Creek Lift Stations,
redundant control system (project No.
96015)
1 Upgrade Middle School L.S. (project No. $40,000 0%
97018)
C",""':,;,;
r, 2 Install Back-flow Control on Bypass Channel $26,000 0%
l i at 10th Street L.S. (project No. 97028)
n 1 Relocate Bar Screens to Influent Channel at $50,000 0%
10th Street L.S. (project No. 97026)
,
t,.,')
1 Upgrade Powerhouse L.S. (project No. $60,000 0%
r
I 97024)
k
1 Upgrade Mill Creek L.S. (project No. $60,000 0%
1 Convert Cedarview L.S. to Gravity Sewer $1,500 0%
(project No. 97021)
1 Install Dry-well Submersible Pumps at $60,000 10%
Street L.S. (project No. 97011)
1 Install Dry-well Submersible Pumps at $60,000 10%
Magnolia L.S, (project No. 97009)
1 Install Dry-well Submersible Pumps at Ewing $60,000 10%
Lane L.S. (project No. 97010)
n:m
,._ " ,_ ','>' .j}'~""",,: ...., :-;.. .. ,._; i ".,
2 Upgrade Camp Powers L.S. (project No. $50,000 0%
97019)
,:.....,.,...:;.:._,.>;..-:,....::...\';.:
r' 1 Upgrade Colonial Park (project No. 96017) $32,000 10%
Lj 2 Replace Rolling Fields With Gravity Sewer $50,000 1 00%
(project No. 96018)
Total Expenditures For $624,500 $0
r
r. 1 Replace 1987 Dodge Ram (project $19,000 $19,500.00 1 00%
.
L 97039)
'-' -.'"" ~'....."'''';''''
1 Replace Boom Truck ( project No. 97()T6) $30,000 0%
$49,000 $19,500
r
l
,......
t
I
~. : " " "'.. -..-- I -~-..."" ".."-
... ,........,.....----"
Attachment I
Safety Inspection Report
r
ENVIRONMENTAL MAFiA.GEMENTCOl1PO]CfTION
MONTllLY, SAfl}TY,INSPECTION
CHECKOFF SHEET
r
[
r
[
[
JEFFERSONVILLE W ASTEW ATER TREATMENT FACILITY
701 CHAMPION ROAD
JEFFERSONVILLE, IN 47130
(812) 285-6451
PERSON COMPLETING INSPECTION:
Kevin W ri2ht
Februarv 27.1998
I. Personnel Safety
A. Personal Protective Clothing
r
"
Il,,,d
1. Safety Helmets Provided
(for Personnel & Visitors)..................................
2. Hearing Protection
(for High Noise Areas).......................................
3. Eye Protection - Goggles, etc.
(for Personnel & Visitors)................................;.
4. Gloves
(for Personnel)... ... .................~ ... ........... .............
5. Rubber Boots with Steel Toes
(provided for Personnel).....................................
6. Rain Suits Provided
(for Personnel)...................................................
7. Is Respiratory Protection Provided including
ventilators and hoods over high dust areas, dust
masks, etc. (for Personnel)................................
[
[
[,
~,'
r
[
B. Safety Devices and Equipment
1. NOll-sparking Toots in areas where flammable
or explosive gases may be present?....................
2. Oxygen Deficiency, Toxic, & Explosive Gas
indicator........................................................ .....
3. Self-contained Breathing Apparatus for entry
to chlorine room,................................................
4. Confined Space Entry Equipment Available
such as and including Safety Harness, Portable
Wench, Hoist, etc... ..................... ........ ...............
5. First Aid Kits with proper & adequate supplies
readily available for any First Aid Emergency....
r
L
[
r
'I
U, ,
r
t,
r
II
~ ,
r
L
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
n
r
r
[
r
[
r
n
r
r
n
[
n
6. Traffic Control Cones A vailabIe........................ Yes NO N/A
7. Ladders to enter manholes of wet wells
(fiberglass or wooden for electrical work)......... Yes NO N/A
8. Safety Buoys and Life Lines, Life Preservers
at all open structures (02 Ditches, Clarifiers,
Lagoons, etc..... .......... ...................... ................ Yes NO N/A
II. General Plant Safety
1. Are Personnel trained in the use and location
of safety equipment at the plariL................... Yes NO N/A
2. Are there railings around all tanks with
openings chained ofL.................................... Yes NO N/A
3. Are holes covered? Including all pits & wells,
drains, valve holes, hatch covers in place........ Yes NO N/A
4. Are explosion proof fixtures used where
needed.................... ....................................... Yes NO N/A
5. Are all equipment guards in place? Including
mowing equipment.....,..... ..... ... ... ........ ..... ...... Yes NO N/A
6. Are dry wells ventilated and is ventilation
adequate in all areas....................................... Yes NO N/A
7. Are emergency numbers posted & accessible.. Yes NO N/A
8. Is proper liquid flammable storage used.......... Yes No> N/A
9. Is general plant cleanliness being practiced?
Including floors (No oil or grease or pools of
water), Storage Areas (No clutter & supplies
stored properly), Chlorine Room (Free of
clutter), Laboratory........................................ Yes No N/A
10. Are all walkways, exists and routes, &
stairways clear & unobstructed (No ice, oils,
water, grease, or debris)................................. Yes NO N/A
11. Are all slippery surfaces posted and/or covered
with anti-skid material, including stair treads
and ramps, in good repair and covered with
non-skid surface... ,.................. ....;................... Yes NO N/A
12. Are all mats and rugs in good repair so as not
to become tripping hazards............................. Yes NO N/A
13. Are work area layouts adequate...................... Yes NO N/A
14. Is lighting adequate in all areas (Work areas,
stairways, walkways, etc.).............................. Yes NO N/A
15. Are noise levels within allowable limits or
danger areas posted..............:.......................... Yes NO N/A
16. Are toilet facilities available & clean............... Yes NO N/A
17. Is safe drinking water available....................... Yes NO N/A
18. Is pest control adequate.................................. Yes NO N/A
19. Are all exists properly marked......................... Yes NO N/A
20. Is inclement weather protection provided at
entrances (mats, safety strips, de-icers, etc.).... Yes NO N/A
r
t__,~
[
[
r
L
r
L
r
il
ik.._,v
[
[
[
r
r
~I
,
r
L
fI
L
r
u,
r
er'""
~ .
~I
ti .
rr-
t!
L
r
Ii
r
tj,,i
II
tl
tj i
r
rr-
~I
ti
t.,;
21. Are tripping hazards eliminated at all doors
(threshold plates in good repair, etc.)..............
22. Is safety glass provided in all doors.................
23. Are handrails provided on stairs (Both sides
if necessary).... ,................,..... ........................
24. Are ladders properly anchored.......................
25. Are fixed.ladders provided with safety cages
or safety side rails.........................................
26. Are all elevation differences between floors
clearly defined and properly lighted................
27. Are portable ladders in good condition...........
28. Kick boards in place if needed........................
29. No Broken steps............................................
30. Are ashtrays provided and emptied regularly..
31. Are trash cans covered and emptied regularly.
32. Are portable hoists for lifting heavy equipment
in good repair...... ................................ ...........
33. Are plant personnel immunized for tetnus.......
34. No electrical cords stretched over tanks..........
35. No gas leaks...................................................
36. Fuel supply tank in good condition.................
37. No excessively hot operating temperature on
machinery or equipment................................
38. No excessive vibration of machinery or
equipment............................;...................... .
39. No water or oil being "slung" from equipment
40. No worn or cracked equipment.....................
41. No excessive dust on equipment...................
42. Adequate dehumidifier and heaters where
needed.. ..........................;.............................
43. Emergency Medical Information on all
employees available for determination of job
assignments............................. .....................
44. Cross connections have been eliminated
between potable water supply and non~potable
source:
a. Pump & Mixer Seals.................................
b. Digester Heating System Makeup Water...
c. Vacuum Filter Water Sprays.....................
d. Chemical Mixing Tank...............................
e. Chlorinator Water Source...........................
f. De-Chlorination Water Source....................
g. Yard Hydrants............................................
h. Other... ..... ... .................. ........ ........ ........ .....
III. Electrical Safety
1. Is all electrical circuitry enclosed and identified.
2. Is all wiring in good condition..........................
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes
Yes
Yes
'Yes
Yes
Yes
Yes
Yes
Yes
Yes
NO
NO
NO
NO
NO
NO
NO
NO
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
NO
NO
N/A
N/A
rr-
fl i
L
[
2. Is proper safety clothing present for the
chemical to be handled............................,....,.
3. Are all containers, vats, and tanks properly
labeled...... ........................... ,.............. '," ,.. ,.....
4. Is employee exposure within accepted limits....
5. Are there proper containment of storage areas,
including curbing..... .......................................
6. Are management & employees aware of the
hazards of the materials being used..................
7. Knows proper response to an accidental spill...
8. All MSDS available and easily accessible.........
9. Has complied with the 6 employer
responsibilities of the Worker Right to Know
Law? (SARA)............... ..................................
10. Emergency Action Plan on file with local Fire,
Police Departments and appropriate Emergency
Agency................... t....................................,...
r
u,,'"
f'r
"
'I
Li
fr
~I
Ii
IL,
r
ij,~"
f'
~I '
IU
VI. Tools & Equipment
,....
~I
~:
1. Are hand tools in good repair and stored
properly......................................................... .
2. Are power tools stored properly and in good
condition - cords, plugs, etc............................
3. Are the tools adequate for the tasks to be
performed....................................................... ,
,4. Are defective tools replaced as needed............
5. Are tool guards in place..................................
6. Are employees trained in the proper use of the
various tools they are expected to use.............
7. Are employees given additional instruction and
periodic reviews of specialized tools and
equipment....................................................... .
8. Are proper lifting techniques used by
employees.......... ................ ..'... ..... ........ ......... to.
[
r
tL~
r
ILi
r
I'
[ .
r
r
VII. Fire Safety & Protection
1. Are fire/emergency evacuation plans posted......
2. Are employees familiar with fire/emergency
evacuation plan.......... ........................ ..............
3. Are there sufficient number and types of fire
extinguishers................................................... .
4. Are the fire extinguishers properly located and
identified....................................................... ...
5. Are the fire extinguishers checked annually......
6. Are all of the fire extinguishers in working
condition........................................................ .
7. Are employees trained in the proper use ofthe
extinguishers to be used...................................
8. Are smoke detectors in working order.............
n
n
r
c
ri:
t,-)
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes No N/A
Yes No N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
Yes NO N/A
/'11
II;
~J
[
[
E
r
~
VIII. Laboratory Safety
1. Emergency Eyewash & Shower Station are
present and work properly and tested monthly.. Yes NO N/A
2. Fume hood is present....................................... Yes NO N/A
3. All chemicals safely and properly stored, well
labeled and in original containers..................... Yes NO N/A
4. Laboratory Safety devices used such as: Pipette
suction bulbs, Eye Protection, Gloves, Aprons
or Jackets, & Tongs................,........................ Yes NO N/A
5. No brokenl chipped or cracked glassware........ Yes NO N/A
6. No overloaded outlets..................................... Yes NO N/A
7. Acid spill kit available....................,....,........... Yes NO N/A
8. Emergency procedures for acid spills posted
and used by all personneL............................. Yes NO N/A
9. Laboratory Safety Rules posted and obeyed by
all personnel such as no cooking or eating from
laboratory glass ware........................................ Yes NO N/A
IX. Other Safety
1. Are the required safety programs presented
and/or attended during the year........................ Yes NO N/A
2. Is a suitable identification system used to
identify the plant's piping system...................... Yes NO N/A
3. Has the operator taken steps to remoVe or
minimize safety hazards.................................. Yes NO N/A
4. Are all personnel provided with a shower and
locker for their work clothes........................... Yes NO N/A
5. Are personnel trained in First Aid & CPR........ Yes NO N/A
6. Have the following proper safety signs been
provided such as: Non-potable Water, Chlorine
Hazard, No Smoking, High Voltage, Watch
Your Step Signs in Certain Areas, & Exit Signs. Yes NO N/A
7. Is your Facility safety program Up to Date
(W orksafe Program)........................................ Yes NO N/A
(# YES)
133-2 x 100= 98.5 %
(# YES + # NO)
[
[
[
r
LJ
[
r
[
[
f!
~
Paint thinner can setting out on counter in kitchen and alos on work bench in garage.
e:\february98\sftyinsp, wpd
r,
t